The AP-5 will retain its memory, even without power. Three dry contact relay outputs are provided. One relay is dedicated for access control, another dedicated for obstacle detection, and the third programmable for either access or obstacle. Access relays can be set for timed or latch-on/latch-off toggle operation. The on or off toggle state of a relay is maintained even after power interruption.
For entrapment detection, obstacle relays activate from MGT safety edge transmitters and connect to the obstacle input of the access device. OPEN REQUEST input terminals are supplied for hardwired activation of the access devices with an external pushbutton or key switch. The AP-5 monitors each MGT safety edge transmitter for hourly status reports, tamper signals, and low battery signals. A beep will sound every 5 seconds if a fault occurs and the trouble source can be displayed. An access transmitter must be activated twice to trigger the access relay if a supervisory trouble condition exists on any MGT transmitter.The AP-5 can be powered from 12-24 Volts AC or DC. The Form C relay outputs can switch up to 1 Amp each. An EARTH GROUND terminal is provided as a recommended connection for maximum lightning and static protection.
Ideal for gated communities, parking facilities, and industrial sites. Easy to set-up and use, up to 480 remotes can be programmed with a few keystrokes. Easy to add, suspend, and delete transmitters through programming mode, no transmitter dip switches to set. Supports 480 block coded transmitters or 238 individual transmitters/wireless keypad entry codes. Supports up to six fully supervised safety edge transmitters. AP-5 replaces Linear's AP-4; AP-5 available for replacement of existing AP-4 units only.